Utah 2025 2025 Regular Session

Utah House Bill HB0313 Enrolled / Bill

Filed 03/14/2025

                    Enrolled Copy	H.B. 313
1 
Construction Industry Amendments
2025 GENERAL SESSION
STATE OF UTAH
Chief Sponsor: Thomas W. Peterson
Senate Sponsor: Calvin R. Musselman
2 
 
3 
LONG TITLE
4 
General Description:
5 
This bill modifies the State Construction Code.
6 
Highlighted Provisions:
7 
This bill:
8 
▸ amends the State Construction Code to:
9 
● align with updated standards in the International Residential Code (IRC); and
10 
● align with the updated standards in the National Electric Code (NEC);
11 
▸ includes a coordination clause to make the amendments to Section 15A-3-202 in this bill
12 
supersede the amendments to Section 15A-3-202 in H.B. 175, Housing Construction
13 
Amendments;
14 
▸ removes regulations for water heaters in certain areas; and
15 
▸ makes technical changes.
16 
Money Appropriated in this Bill:
17 
None
18 
Other Special Clauses:
19 
This bill provides a special effective date.
20 
This bill provides a coordination clause.
21 
Utah Code Sections Affected:
22 
AMENDS:
23 
15A-2-103, as last amended by Laws of Utah 2024, Chapter 505
24 
15A-3-105, as last amended by Laws of Utah 2024, Chapter 505
25 
15A-3-202, as last amended by Laws of Utah 2024, Chapter 505
26 
15A-3-206, as last amended by Laws of Utah 2024, Chapter 505
27 
15A-3-601, as last amended by Laws of Utah 2024, Chapter 15 H.B. 313	Enrolled Copy
28 
19-2-107.7, as enacted by Laws of Utah 2016, Chapter 247
29 
Utah Code Sections affected by Coordination Clause:
30 
15A-3-202, as last amended by Laws of Utah 2024, Chapter 505
31 
 
32 
Be it enacted by the Legislature of the state of Utah:
33 
Section 1.  Section 15A-2-103 is amended to read:
34 
15A-2-103 . Specific editions adopted of construction code of a nationally
35 
recognized code authority.
36 
(1) Subject to the other provisions of this part, the following construction codes are
37 
incorporated by reference, and together with the amendments specified in Chapter 3,
38 
Statewide Amendments Incorporated as Part of State Construction Code, and Chapter 4,
39 
Local Amendments Incorporated as Part of State Construction Code, are the
40 
construction standards to be applied to building construction, alteration, remodeling, and
41 
repair, and in the regulation of building construction, alteration, remodeling, and repair
42 
in the state:
43 
(a) the 2021 edition of the International Building Code, including Appendices C and J,
44 
issued by the International Code Council;
45 
(b) the 2021 edition of the International Residential Code, issued by the International
46 
Code Council;
47 
(c) Appendix AQ of the 2021 edition of the International Residential Code, issued by the
48 
International Code Council;
49 
(d) the 2021 edition of the International Plumbing Code, issued by the International
50 
Code Council;
51 
(e) the 2021 edition of the International Mechanical Code, issued by the International
52 
Code Council;
53 
(f) the 2021 edition of the International Fuel Gas Code, issued by the International Code
54 
Council;
55 
(g) the [2020] 2023 edition of the National Electrical Code, issued by the National Fire
56 
Protection Association;
57 
(h) the 2021 edition of the International Energy Conservation Code, issued by the
58 
International Code Council;
59 
(i) the 2021 edition of the International Existing Building Code, issued by the
60 
International Code Council;
61 
(j) subject to Subsection 15A-2-104(2), the HUD Code;
- 2 - Enrolled Copy	H.B. 313
62 
(k) subject to Subsection 15A-2-104(1), Appendix AE of the 2021 edition of the
63 
International Residential Code, issued by the International Code Council;
64 
(l) subject to Subsection 15A-2-104(1), the 2005 edition of the NFPA 225 Model
65 
Manufactured Home Installation Standard, issued by the National Fire Protection
66 
Association;
67 
(m) subject to Subsection (3), for standards and guidelines pertaining to plaster on a
68 
historic property, as defined in Section 9-8a-302, the U.S. Department of the Interior
69 
Secretary's Standards for Rehabilitation and Guidelines for Rehabilitating Historic
70 
Buildings;[ and]
71 
(n) the residential provisions of the 2021 edition of the International Swimming Pool
72 
and Spa Code, issued by the International Code Council; and
73 
(o) Modular Building Institute Standards 1200 and 1205, issued by the International
74 
Code Council, except as modified by provisions of this title governing modular units.
75 
(2) Consistent with Title 65A, Chapter 8, Management of Forest Lands and Fire Control,
76 
the Legislature adopts the 2006 edition of the Utah Wildland Urban Interface Code,
77 
issued by the International Code Council, with the alternatives or amendments approved
78 
by the Utah Division of Forestry, Fire, and State Lands, as a construction code that may
79 
be adopted by a local compliance agency by local ordinance or other similar action as a
80 
local amendment to the codes listed in this section.
81 
(3) The standards and guidelines described in Subsection (1)[(n) ] (m) apply only if:
82 
(a) the owner of the historic property receives a government tax subsidy based on the
83 
property's status as a historic property;
84 
(b) the historic property is wholly or partially funded by public money; or
85 
(c) the historic property is owned by a government entity.
86 
Section 2.  Section 15A-3-105 is amended to read:
87 
15A-3-105 . Amendments to Chapters 10 through 12 of IBC.
88 
(1) In IBC, Section 1010.2.4, number (2), the following is added at the end of the sentence:
89 
"Blended assisted living facilities shall comply with Section 1010.2.14.1."
90 
(2) A new IBC Section 1010.2.14.1 is added as follows: "1010.2.14.1 Blended assisted
91 
living facilities. In occupancy Group I-1, Condition 2 or Group I-2, a Type-II assisted
92 
living facility licensed by the Department of Health and Human Services for residents
93 
with Alzheimer's or dementia, and having a controlled egress locking system to prevent
94 
operation from the egress side shall be permitted to also house residents without a
95 
clinical need for their containment where all of the following provisions are met:
- 3 - H.B. 313	Enrolled Copy
96 
(a) locks in the means of egress comply with all IBC requirements for controlled egress
97 
doors;
98 
(b) all residents without a clinical need for their containment shall have the keys, codes,
99 
or other means necessary to exit the facility, in a manner that is determined by the
100 
facility operator and communicated to the resident or their legal representative;
101 
(c) residents or their legal representative acknowledge in writing that they understand
102 
and agree to living in a facility where egress is controlled; and
103 
(d) the number of residents housed in a smoke compartment with controlled egress shall
104 
not be greater than 30."
105 
(3) In IBC, Section 1011.5.2, exception 3 is deleted and replaced with the following: " 3.  In
106 
Group R-3 occupancies, within dwelling units in Group R-2 occupancies, and in Group
107 
U occupancies that are accessory to a Group R-3 occupancy, or accessory to individual
108 
dwelling units in Group R-2 occupancies, the maximum riser height shall be 8 inches
109 
(203 mm) and the minimum tread depth shall be 9 inches (229 mm).  The minimum
110 
winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum
111 
winder tread depth shall be 6 inches (152 mm).  A nosing not less than 0.75 inch (19.1
112 
mm) but not more than 1.25 inches (32 mm) shall be provided on stairways with solid
113 
risers where the tread depth is less than 10 inches (254 mm)."
114 
(4) In IBC, Section 1011.11, a new exception 6 is added as follows: " 6.  In occupancies in
115 
Group R-3, as applicable in Section 101.2 and in occupancies in Group U, which are
116 
accessory to an occupancy in Group R-3, as applicable in Section 101.2, handrails shall
117 
be provided on at least one side of stairways consisting of four or more risers."
118 
(5) In IBC, Section 1025, is deleted.
119 
(6) In IBC, Section 1104.4, exception 1.5 is deleted.
120 
The following section is affected by a coordination clause at the end of this bill.
121 
Section 3.  Section 15A-3-202 is amended to read:
122 
15A-3-202 . Amendments to Chapters 1 through 5 of IRC.
123 
(1) In IRC, Section R101.2, Exception, the words "where provided with an automatic
124 
sprinkler system complying with Section P2904" are deleted.
125 
(2) In IRC, Section R101.2, Exception, the words "6. A triplex or fourplex of no more than
126 
two levels with 2-hour fire-resistance-rated vertical shared wall assemblies tested in
127 
accordance with ASTM E119 or UL263, 1-hour fire-resistance-rated horizontal floor
128 
assemblies tested in accordance with ASTM E119 or UL263, and independent egress for
129 
each unit." are added.
- 4 - Enrolled Copy	H.B. 313
130 
[(2)] (3) In IRC, Section R102, a new Section R102.7.2 is added as follows: "R102.7.2
131 
Physical change for bedroom window egress.  A structure whose egress window in an
132 
existing bedroom is smaller than required by this code, and that complied with the
133 
construction code in effect at the time that the bedroom was finished, is not required to
134 
undergo a physical change to conform to this code if the change would compromise the
135 
structural integrity of the structure or could not be completed in accordance with other
136 
applicable requirements of this code, including setback and window well requirements."
137 
[(3)] (4) In IRC Section R105.2, under Building, the following changes are made:
138 
(a) Number 3 is deleted and replaced with the following: "3. Retaining walls retaining
139 
less than 4 feet (1219mm) of unbalanced fill, unless supporting a surcharge or
140 
requiring design per Section R404.4."
141 
(b) Number 10 is deleted and replaced with the following: "10. Decks that are not more
142 
than 30 inches (762mm) above grade at any point and not requiring guardrails, that
143 
do not serve exit door required by Section R311.4."
144 
[(4)] (5) In IRC, Section R105.2, a new exception is added: "11. Grade level, non-connected
145 
conex boxes, less than 350 square feet, used for storage only."
146 
[(5)] (6) In IRC, Section R108.3, the following sentence is added at the end of the section:
147 
"The building official shall not request proprietary information."
148 
[(6)] (7) In IRC, Section 109.1.5, is deleted and replaced with the following: "R109.1.5
149 
Other inspections. In addition to the inspections listed in R109.1.1 through R109.1.4, the
150 
building official shall have the authority to inspect the proper installation of insulation.
151 
R109.1.5.1 Weather-resistant exterior wall envelope inspections. An inspection shall be
152 
made of the weather-resistant exterior wall envelope as required by Section R703.1 and
153 
flashings as required by Section R703.4 to prevent water from entering the
154 
weather-resistive barrier.R109.1.5.2 Fire-resistance-rated construction inspection. Where
155 
fire-resistance-rated construction is required between dwelling units or due to location
156 
on property, the building official shall require an inspection of such construction after
157 
lathing or gypsum board or gypsum panel products are in place, but before any plaster is
158 
applied, or before board or panel joints and fasteners are taped and finished."
159 
[(7)] (8) In IRC, Section R202, the following definition is added: "ACCESSORY
160 
DWELLING UNIT: A habitable living unit created within the existing footprint of a
161 
primary owner-occupied single-family dwelling."
162 
[(8)] (9) In IRC, Section R202, the definition for "Approved" is modified by adding the
163 
words "or independent third-party licensed engineer or architect and submitted to the
- 5 - H.B. 313	Enrolled Copy
164 
building official" after the word "official."
165 
[(9)] (10) In IRC, Section R202, the definition for "Approved Agency" is modified by
166 
replacing the word "and" with "or."
167 
[(10)] (11) In IRC, Section 202, the definition for "Approved Source" is modified by adding
168 
the words "or licensed engineer or architect" after the word "official."
169 
[(11)] (12) In IRC, Section R202, the following definition is added: "CERTIFIED
170 
BACKFLOW PREVENTER ASSEMBLY TESTER: A person who has shown
171 
competence to test Backflow prevention assemblies to the satisfaction of the authority
172 
having jurisdiction under Utah Code, Subsection 19-4-104(4)."
173 
[(12)] (13) In IRC, Section R202, the definition of "Cross Connection" is deleted and
174 
replaced with the following: "CROSS CONNECTION.  Any physical connection or
175 
potential connection or arrangement between two otherwise separate piping systems,
176 
one of which contains potable water and the other either water of unknown or
177 
questionable safety or steam, gas, or chemical, whereby there exists the possibility for
178 
flow from one system to the other, with the direction of flow depending on the pressure
179 
differential between the two systems (see "Backflow, Water Distribution")."
180 
[(13)] (14) In IRC, Section 202, the following definition is added: "DUAL SOURCE
181 
CONNECTION. A pipe that is installed so that either the nonpotable (i.e. secondary)
182 
irrigation water or the potable water is connected to a pressurized irrigation system at
183 
one time, but not both at the same time; or a pipe that is installed so that either the
184 
potable water or private well water is connected to a residence at one time, but not both
185 
at the same time. The potable water supply line shall be protected by a reduced pressure
186 
backflow preventer."
187 
[(14)] (15) In IRC, Section 202, the following definition is added: "ENERGY STORAGE
188 
SYSTEM (ESS). One or more devices, assembled together, that are capable of storing
189 
energy for supplying electrical energy at a future time."
190 
[(15)] (16) In IRC, Section 202, in the definition for gray water a comma is inserted after the
191 
word "washers"; the word "and" is deleted; and the following is added to the end: "and
192 
clear water wastes which have a pH of 6.0 to 9.0; are non-flammable; non-combustible;
193 
without objectionable odors; non-highly pigmented; and will not interfere with the
194 
operation of the sewer treatment facility."
195 
[(16)] (17) In IRC, Section R202, the definition of "Potable Water" is deleted and replaced
196 
with the following: "POTABLE WATER.  Water free from impurities present in
197 
amounts sufficient to cause disease or harmful physiological effects and conforming to
- 6 - Enrolled Copy	H.B. 313
198 
the Utah Code, Title 19, Chapter 4, Safe Drinking Water Act, and Title 19, Chapter 5,
199 
Water Quality Act, and the regulations of the public health authority having jurisdiction."
200 
[(17)] (18) In IRC, Figure R301.2 (3), is deleted and replaced with R301.2 (3) as follows:
201 	"TABLE R301.2 (3)202 
GROUND SNOW LOADS FOR SELECTED LOCATIONS IN UTAH
203 
City/Town County Ground Snow Load (lb/ft2)Elevation (ft)
204 
Beaver	Beaver 35	5886
205 
Brigham City Box Elder 42	4423
206 
Castle Dale Emery 32	5669
207 
Coalville Summit 57	5581
208 
Duchesne Duchesne 39	5508
209 
Farmington Davis 35	4318
210 
Fillmore Millard 30	5138
211 
Heber City Wasatch 60	5604
212 
Junction Piute 27	6030
213 
Kanab	Kane 25	4964
214 
Loa	Wayne 37	7060
215 
Logan	Cache 43	4531
216 
Manila	Daggett 26	6368
217 
Manti	Sanpete 37	5620
218 
Moab	Grand 21	4029
219 
Monticello San Juan 67	7064
220 
Morgan	Morgan 52	5062
221 
Nephi	Juab 39	5131
222 
Ogden	Weber 37	4334
223 
Panguitch Garfield 41	6630
224 
Parowan Iron 32	6007
225 
Price	Carbon 31	5558
- 7 - H.B. 313	Enrolled Copy
226 	Provo	Utah 31	4541227 
Randolph Rich 50	6286
228 
Richfield Sevier 27	5338
229 
St. George Washington 21	2585
230 
Salt Lake City Salt Lake 28	4239
231 
Tooele	Tooele 35	5029
232 
Vernal	Uintah 39	5384
233 
Note: To convert lb/ft2 to kN/m2, multiply by 0.0479. To convert feet to meters, multiply by 0.3048.1.
Statutory requirements of the Authority Having Jurisdiction are not included in this state ground snow
load table.
2. For locations where there is substantial change in altitude over the city/town, the load applies at and
below the cited elevation, with a tolerance of 100 ft (30 m).
3. For other locations in Utah, see Bean, B., Maguire, M., Sun, Y. (2018), "The Utah Snow Load
Study," Utah State University Civil and Environmental Engineering Faculty Publications, Paper 3589,
http://utahsnowload.usu.edu/, for ground snow load values."
234 
[(18)] (19) In IRC, Section R301.6, is deleted and replaced with the following: "R301.6
235 
Utah Snow Loads.  The snow loads specified in Table R301.2(5b) shall be used for the
236 
jurisdictions identified in that table.  Otherwise, for other locations in Utah, see Bean,
237 
B., Maguire, M., Sun, Y. (2018), "The Utah Snow Load Study," Utah State University
238 
Civil and Environmental Engineering Faculty Publications, Paper 3589,
239 
http://utahsnowload.usu.edu/, for ground snow load values."
240 
[(19)] (20) In IRC, Section R302.2, the following sentence is added at the end of the
241 
paragraph: "When an access/maintenance agreement or easement is in place, plumbing,
242 
mechanical ducting, schedule 40 steel gas pipe, and electric service conductors including
243 
feeders, are permitted to penetrate the common wall at grade, above grade, or below
244 
grade."
245 
[(20)] (21) In IRC, Section R302.3, a new exception 3 is added as follows: "3. Accessory
246 
dwelling units separated by walls or floor assemblies protected by not less than 1/2-inch
247 
(12.7 mm) gypsum board or equivalent on each side of the wall or bottom of the floor
248 
assembly are exempt from the requirements of this section."
249 
[(21)] (22) In IRC, Section R302.5.1, the last sentence is deleted.
250 
[(22)] (23) In IRC, Section R302.13, is deleted.
- 8 - Enrolled Copy	H.B. 313
251 
[(23)] (24) In IRC, Section R303.4, the following exception is added: "Exception: Dwelling
252 
units tested in accordance with Section N1102.4.1.2 (R402.4.1.2) which has an air
253 
tightness of 3.0 ACH (50) or greater do not require mechanical ventilation."
254 
[(24)] (25) In IRC, Section R310.1, all words in the last sentence after "or to a yard or
255 
court", are deleted, and Exception 3 of this section is deleted.
256 
[(25)] (26) In IRC, Section R310.7, in the exception, the words "or accessory dwelling
257 
units" are added after the words "sleeping rooms".
258 [(26)] (27) IRC, Sections R311.7.45 through R311.7.5.3, are deleted and replaced with the
259 
following: "R311.7.45.1 Stair treads and risers. R311.7.5.1 Riser height.  The maximum riser
260 
height shall be 8 inches (203 mm).  The riser shall be measured vertically between leading
261 
edges of the adjacent treads.  The greatest riser height within any flight of stairs shall not
262 
exceed the smallest by more than 3/8 inch (9.5 mm).
263 
      R311.7.5.2 Tread depth.  The minimum tread depth shall be 9 inches (228 mm).  The
264 
tread depth shall be measured horizontally between the vertical planes of the foremost
265 
projection of adjacent treads and at a right angle to the tread's leading edge.  The greatest tread
266 
depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).
267 
Winder treads shall have a minimum tread depth of 10 inches (254 mm) measured as above at
268 
a point 12 inches (305 mm) from the side where the treads are narrower.  Winder treads shall
269 
have a minimum tread depth of 6 inches (152 mm) at any point.  Within any flight of stairs, the
270 
greatest winder tread depth at the 12-inch (305 mm) walk line shall not exceed the smallest by
271 
more than 3/8 inch (9.5 mm).
272 
      R311.7.5.3 Nosing.  The radius of curvature at the leading edge of the tread shall be no
273 
greater than 9/16 inch (14.3 mm).  A nosing not less than 3/4 inch (19 mm) but not more than
274 
1 1/4 inches (32 mm) shall be provided on stairways with solid risers.  The greatest nosing
275 
projection shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm)
276 
between two stories, including the nosing at the level of floors and landings.  Beveling of
277 
nosing shall not exceed 1/2 inch (12.7 mm).  Risers shall be vertical or sloped from the
278 
underside of the leading edge of the tread above at an angle not more than 30 degrees (0.51
279 
rad) from the vertical.  Open risers are permitted, provided that the opening between treads
280 
does not permit the passage of a 4-inch diameter (102 mm) sphere.
281 
      Exceptions.
282 
      1.  A nosing is not required where the tread depth is a minimum of 10 inches (254 mm).
283 
      2.  The opening between adjacent treads is not limited on stairs with a total rise of 30
284 
inches (762 mm) or less."
- 9 - H.B. 313	Enrolled Copy
285 
[(27)] (28) In IRC, Section R312.2, is deleted.
286 
[(28)] (29) In IRC, Sections R313.1 through R313.2.1, are deleted and replaced with the
287 
following: "R313.1 Design and installation.  When installed, automatic residential fire
288 
sprinkler systems for townhouses or one- and two-family dwellings shall be designed
289 
and installed in accordance with Section P2904 or NFPA 13D."
290 
[(29)] (30) In IRC, Section R314.2.2, the words "accessory dwelling units," are added after
291 
the words "Where alterations, repairs."
292 
[(30)] (31) In IRC, Section R315.2.2, the words "accessory dwelling units," are added after
293 
the words "Where alterations, repairs."
294 
[(31)] (32) In IRC, Section 315.3, the following words are added to the first sentence after
295 
the word "installed": "on each level of the dwelling unit and."
296 [(32)] (33) A new IRC, Section R328.12, is added as follows:
297 
      "R328.12 Signage. A sign located on the exterior of the dwelling shall be installed at a
298 
location approved by the authority having jurisdiction which identifies the battery chemistry
299 
included in the ESS. This sign shall be of sufficient durability to withstand the environment
300 
involved and shall not be handwritten."
301 
[(33)] (34) In IRC, Section 403.1.3.5.3, an exception is added as follows: "Exception:
302 
Vertical steel in footings shall be permitted to be located while concrete is still plastic
303 
and before it has set. Where vertical steel resists placement or the consolidation of
304 
concrete around steel is impeded, the concrete shall be vibrated to ensure full contact
305 
between the vertical steel and concrete."
306 
[(34)] (35) In IRC, Section R403.1.6, a new Exception 3 is added as follows: "3.  When
307 
anchor bolt spacing does not exceed 32 inches (813 mm) apart, anchor bolts may be
308 
placed with a minimum of two bolts per plate section located not less than 4 inches (102
309 
mm) from each end of each plate section at interior bearing walls, interior braced wall
310 
lines, and at all exterior walls."
311 
[(35)] (36) In IRC, Section R403.1.6.1, a new exception is added at the end of Item 2 and
312 
Item 3 as follows: "Exception: When anchor bolt spacing does not exceed 32 inches
313 
(816 mm) apart, anchor bolts may be placed with a minimum of two bolts per plate
314 
section located not less than 4 inches (102 mm) from each end of each plate section at
315 
interior bearing walls, interior braced wall lines, and at all exterior walls."
316 
[(36)] (37) In IRC, Section R404.1, a new exception is added as follows: "Exception: As an
317 
alternative to complying with Sections R404.1 through R404.1.5.3, concrete and
318 
masonry foundation walls may be designed in accordance with IBC Sections 1807.1.5
- 10 - Enrolled Copy	H.B. 313
319 
and 1807.1.6 as amended in Section 1807.1.6.4 and Table 1807.1.6.4 under these rules."
320 
[(37)] (38) In IRC, Section R405.1, a second exception is added as follows: "Exception:
321 
When a geotechnical report has been provided for the property, a drainage system is not
322 
required unless the drainage system is required as a condition of the geotechnical report.
323 
The geotechnical report shall make a recommendation regarding a drainage system."
324 
[(38)] (39) In IRC, Section R506.2.3, the words "10-mil (0.010 inch; 0.25 mm)" are deleted
325 
and replaced with "6-mil (0.006 inch; 0.152 mm)" and the words "conforming to ASTM
326 
E1745 Class A requirements" are deleted.
327 
(40) In IRC, Section 507.2.1, Wood materials. The following sentence is added after the
328 
words, "in accordance with section R317," "field applied weather resistant barrier
329 
applied to the top of untreated material,".
330 
Section 4.  Section 15A-3-206 is amended to read:
331 
15A-3-206 . Amendments to Chapters 36, 37, 39, and 44 and Appendix F of IRC.
332 
(1) In IRC, Section E3601.6.2, a new exception is added as follows: "Exception: An
333 
occupant of an accessory dwelling unit is not required to have access to the disconnect
334 
serving the dwelling unit in which they reside."
335 
(2) IRC, Section E3606.5, is deleted.
336 (3) IRC, Section E3601.7, is deleted and replaced with the following:
337 
"3601.7 Maximum number of disconnects. The service disconnecting means shall consist of
338 
not more than six switches or six sets of circuit breakers mounted in a single enclosure or in a
339 
group of separate enclosures."
340 
(4) In IRC, Section E3705.4.4, the following sentences are deleted:
341 
"Where more than two NM cables containing two or more current-carrying
342 
conductors are installed, without maintaining space between the cables, through the
343 
same opening in wood framing should be sealed with thermal insulation, caulk or
344 
sealing foam. The allowable ampacity of each conductor shall be adjusted in accordance
345 
with Table E3705.3 and the provisions of Section E3701.3. Exception. may not apply."
346 (5) IRC, Section E3901.4.2, is deleted and replaced with the following:
347 
      "E3901.4.2 Island and Peninsular Countertops and Work Spaces. Receptacle outlets, if
348 
installed to serve an island or peninsular countertop or work surface, shall be installed in
349 
accordance with E3901.4.3. If a receptacle outlet is not provided to serve an island or
350 
peninsular countertop or work surface, provisions shall be provided at the island or peninsula
351 
for future addition of a receptacle outlet to serve the island or peninsular countertop or work
352 
surface."
- 11 - H.B. 313	Enrolled Copy
353 
[(5)] (6) IRC, Section E3901.4.3, is deleted and replaced with the following:
354 
      "E3901.4.3 Receptacle Outlet Location. [Receptacle] When installed, receptacle outlets
355 
shall be located in one or more of the following:
356 
      1. On or above, but not more than 20 inches (508 mm) above a countertop or work
357 
surface.
358 
      2. In a countertop using receptacle outlet assemblies listed for use in countertops.
359 
      3. In a work surface using receptacle outlet assemblies listed for use in work surface or
360 
listed for use in countertops.
361 
      Receptacle outlets rendered not readily accessible by appliances fastened in place,
362 
appliance garages, sinks, or range tops as covered in the exception to Section E3901.4.1 or
363 
appliances occupying assigned spaces shall not be considered as these required outlets.
364 
      4. Under the countertop not more than 14 inches from the bottom leading edge of the
365 
countertop."
366 
[(6)] (7) In IRC, Section 3902.1, after the word "125-volt" add "single phase 15 and 20
367 
ampere" and strike the words "through 250 volt."
368 
[(7)] (8) In IRC, Section 3902.2, after the word "125-volt" add "single phase 15 and 20
369 
ampere" and strike the words "through 250 volt."
370 
[(8)] (9) In IRC, Section 3902.3, after the word "125-volt" add "single phase 15 and 20
371 
ampere" and strike the words "through 250 volt."
372 
[(9)] (10) In IRC, Section 3902.4, after the word "125-volt" add "single phase 15 and 20
373 
ampere" and strike the words "through 250 volt."
374 
[(10)] (11) In IRC, Section 3902.5, after the word "125-volt" add the words "single phase 15
375 
and 20 ampere in unfinished portions of the basement shall have ground-fault
376 
circuit-interrupter protection for personnel" and delete the rest of the section.
377 
[(11)] (12) In IRC, Section 3902.6, after the word "125-volt" add "single phase 15 and 20
378 
ampere" and strike the words "through 250 volt."
379 
[(12)] (13) In IRC, Section 3902.7, after the word "125-volt" add "single phase 15 and 20
380 
ampere" and strike the words "through 250 volt."
381 
[(13)] (14) In IRC, Section 3902.8, after the word "125-volt" add "single phase 15 and 20
382 
ampere" and strike the words "through 250 volt."
383 
[(14)] (15) In IRC, Section 3902.9, after the word "125-volt" add "single phase 15 and 20
384 
ampere" and strike the words "through 250 volt."
385 
[(15)] (16) IRC, Section 3902.10, is deleted.
386 
[(16)] (17) In IRC, Section 3902.12, after the word "125-volt" add "single phase 15 and 20
- 12 - Enrolled Copy	H.B. 313
387 
ampere" and strike the words "through 250 volt."
388 
[(17)] (18) In IRC, Section 3902.13, after the word "125-volt" add "single phase 15 and 20
389 
ampere" and strike the words "through 250 volt."
390 
[(18)] (19) IRC, Section 3902.15, Crawl space lighting outlets, is deleted.
391 
[(19)] (20) IRC, Section 3902.16, Equipment requiring servicing, is deleted.
392 
[(20)] (21) IRC Section 3902.17, Outdoor outlets, is deleted.
393 
[(21)] (22) IRC, Section 3902.19, Location of arc-fault circuit interrupters, is deleted.
394 
[(22)] (23) IRC, Section E3902.20, Arc-fault circuit interrupter protection, is deleted.
395 
[(23)] (24) IRC, Section E3902.21, Arc-fault circuit interrupter protection for branch circuit
396 
extensions or modification, is deleted.
397 
[(24)] (25) IRC, Section 4002.11, is deleted and replaced with the following: "4002.11
398 
Bathtub and Shower Space. Receptacles shall not be installed within or directly over a
399 
bathtub or shower stall."
400 
[(25)] (26) IRC, Chapter 44, is amended by deleting the standard for "ANCE."
401 
[(26)] (27) In IRC, Chapter 44, the standard for ASHRAE is amended by changing
402 
"34-2013" to "34-2019."
403 
[(27)] (28) In IRC, Chapter 44, the standard for CSA, is amended by changing the:
404 
(a) standard reference number "UL/CSA/ANCE 60335-2-40-2012" to "UL/CSA
405 
60335-2-40-2019"; and
406 
(b) title "Standard for Household and Similar Electrical Appliances, Part 2: Particular
407 
Requirements for Motor-Compressors" to "Standard for Household and Similar
408 
Electrical Appliances, Part 2-40, Requirements for Electric Heat Pumps, Air
409 
Conditioners and Dehumidifiers-3rd Edition."
410 
[(28)] (29) In IRC, Chapter 44, the standard for UL, is amended by changing the:
411 
(a) standard reference number "1995-2011" to "1995-2015";
412 
(b) standard reference number "UL/CSA/ANCE 60335-2-40-2012" to "UL/CSA
413 
60335-2-40-2019"; and
414 
(c) title "Standard for Household and Similar Electrical Appliances, Part 2: Particular
415 
Requirements for Motor-Compressors" to "Standard for Household and Similar
416 
Electrical Appliances, Part 2-40, Requirements for Electric Heat Pumps, Air
417 
Conditioners and Dehumidifiers-3rd Edition."
418 [(29)] (30) In IRC, Chapter 44, the standard for ANSI/RESNET/ICC 201-2019 Section 4.4.4 is
419 
added as follows: "4.4.4. Air Source Heat Pumps and Air Conditioners. For Heat Pumps and
420 
Air Conditioners with the more recent Manufacturers Equipment Performance Ratings (HSPF2
- 13 - H.B. 313	Enrolled Copy
421 
or SEER2) available, and HSPF and SEER are not available, these ratings shall be converted
422 
to HSPF and SEER values by dividing HSPF2 or SEER2 by the conversion factors in Table
423 
4.4.4.1(1).  If the type of equipment is not determined, the conversion shall default to the
424 
Ducted Split System factors.  All calculations, including Equation 4.1-1a shall use HSPF or
425 
SEER values as made available by the Manufacturer or converted as specified in this section.
426 
Table 4.4.4.1(1) SEER2 and HSPF2 Conversion Factors3.
427 	Equipment Type	SEER2/SEEREER/EER4 HSPF/HSPF428 
Ductless Systems	1.00 1.00 0.90
429 
Ducted Split System	0.95 0.95 0.85
430 
Ducted Package System	0.95 0.95 0.84
431 
Small Duct High Velocity System	1.00 not applicable0.85
432 
Ducted Space-Constrained Air Conditioner 0.97 not applicablenot applicable
433 
Ducted Space-Constrained Heat Pump	not applicable0.85"
434 [(30)] (31) IRC, Chapter 44, is amended by adding the following reference standard:
435 
436 	"Standard reference numberTitle	Referenced in code
section number
437 
USC-FCCCHR 10th
Edition Manual of Cross
Connection Control
Foundation for Cross-Connection Control and
Hydraulic Research University of Southern
California Kaprielian Hall 300 Los Angeles
CA 90089-2531
Table P2902.3"
438 
[(31)] (32) IRC, Chapter 44, is amended by adding the following reference standard: "UL
439 
9540-20: Energy Storage Systems and Equipment; R328.1, R328.2, and R328.6."
440 
[(32)] (33)(a) When passive radon controls or portions thereof are voluntarily installed,
441 
the voluntary installation shall comply with Appendix F of the IRC.
442 
(b) An additional inspection of a voluntary installation described in Subsection [(27)(a) ] 
443 
(28)(a) is not required.
444 
Section 5.  Section 15A-3-601 is amended to read:
445 
15A-3-601 . General provisions.
446 
      The following are adopted as amendments to the NEC to be applicable statewide:
447 
(1) The IRC provisions are adopted as the residential electrical standards applicable to
448 
residential installations under the IRC.  All other installations shall comply with the
449 
adopted NEC.
- 14 - Enrolled Copy	H.B. 313
450 
(2) In NEC, Section 210.8(A), the words "through 250-volt" are deleted.
451 
(3) In NEC, Section 210.8(A) number (5), the word "Basements" is deleted and replaced
452 
with the following:
453 
"Unfinished portions or areas of the basement not intended as habitable rooms."
454 
(4) In NEC, Section 210.8(A), number (6), the following is added after the word "Kitchens":
455 
"where the receptacles are installed to serve the countertop surfaces."
456 
(5) In NEC, Section 210.8(A), number (7) is deleted.
457 
(6) In NEC, Section 210.8(D), numbers (8) through (12) are deleted.
458 
(7) NEC, Section 210.8(F), is deleted.
459 [(5)] (8) NEC, Sections 210.52(C) number (2) and number (3) are deleted and replaced with the
460 
following:
461 
      "210.52(C)(2) Island and peninsular countertops and Work Surfaces. Receptacle outlets,
462 
if installed to serve an island or peninsular countertop or work surface, shall be installed in
463 
accordance with 210.52(C)(3). If a receptacle outlet is not provided to serve an island or
464 
peninsular countertop or work surface, provisions shall be provided at the island or peninsula
465 
for future addition of a receptacle outlet to serve the island or peninsular countertop or work
466 
surface.
467 
      210.2(C)(3) Receptacle outlet location. Receptacle outlets shall be located in one or
468 
more of the following:
469 
(a) On or above, but not more than 500 mm (20 inches) above a countertop or work
470 
surface.
471 
(b) In a countertop using receptacle assemblies listed for use in countertops.
472 (c) In a work surface using receptacle outlet assemblies listed for use in work surfaces or listed
473 
for use in countertops.
474 
      Receptacle outlets rendered not readily accessible by appliances fastened in place,
475 
appliance garages, sinks, or range tops as covered in the exception to 210.52(C)(1), occupying
476 
assigned spaces shall not be considered as these required outlets.
477 
      Exception: In dwelling units designed to be accessible to persons with disabilities,
478 
receptacles shall be permitted to be installed not more than 300 mm (12 inches) below the
479 
countertop or work surface. Receptacles installed below a countertop or work surface shall not
480 
be located where the countertop or work surface extends more than 150 mm (6 inches) beyond
481 
its support or base."
482 
[(6)] (9) NEC, Section 210.12, is deleted.
483 
[(7)] (10) NEC, Section 210.65, is deleted.
- 15 - H.B. 313	Enrolled Copy
484 
(11) NEC, Section 215.18, is deleted.
485 
(12) NEC, Section 225.42 is deleted.
486 
[(8)] (13) NEC, Section 230.67, is deleted.
487 [(9)] (14) NEC, Section 230.71, is deleted and replaced with the following:
488 
"230.71 Maximum Number of Disconnects.
489 
(A) General. The service disconnecting means for each service permitted by 230.2, or for
490 
each set of service-entrance conductors permitted by 230.40, Exception No. 1, 3, 4, or 5 shall
491 
consist of not more than six switches or sets of circuit breakers, or a combination of not more
492 
than six switches and sets of circuit breakers, mounted in a single enclosure, in a group of
493 
separate enclosures, or in or on a switchboard or in switchgear. There shall be not more than
494 
six sets of disconnects per service grouped in any one location. For the purpose of this section,
495 
disconnecting means installed as part of listed equipment and used solely for the following
496 
shall not be considered a service disconnecting means:
497 
(1) Power monitoring equipment;
498 
(2) Surge-protective device(s);
499 
(3) Control circuit of the ground-fault protection system; or
500 
(4) Power-operable service disconnecting.
501 
(B) Single-Pole Units. Two or three single-pole switches or breakers, capable of individual
502 
operation, shall be permitted on multiwire circuits, one pole for each ungrounded conductor, as
503 
one multipole disconnect, provided they are equipped with identified handle ties or a master
504 
handle to disconnect all conductors of the service with no more than six operations of the hand.
505 
(C) Beginning on July 1, 2027, Section 230.71(B) is no longer in effect."
506 
[(10)] (15) NEC, Section 314.27(C), is deleted and replaced with the following: "314.27(C)
507 
Boxes at Ceiling-Suspended (Paddle) Fan Outlets. Outlet boxes or outlet box systems
508 
used as the sole support of a ceiling-suspended (paddle) fan shall be listed, shall be
509 
marked by their manufacturer as suitable for this purpose, and shall not support
510 
ceiling-suspended (paddle) fans that weigh more than 32 kg (70 lb). For outlet boxes or
511 
outlet box systems designed to support ceiling-suspended (paddle) fans that weigh more
512 
than 16 kg (35 lb), the required marking shall include the maximum weight to be
513 
supported."
514 
(16) In NEC, Section 334.24, the last sentence is deleted and replaced with the following:
515 
"For flat cables, the minor diameter dimension of the cable shall be used to determine
516 
the bending radius when bending on the flat side of the cable. For all other bends, the
517 
major diameter dimension shall be used."
- 16 - Enrolled Copy	H.B. 313
518 
[(11) NEC, Section 406.9(C), is deleted and replaced with the following: "406.9(C) Bathtub
519 
and Shower Space. Receptacles shall not be installed within or directly over a bathtub or
520 
shower stall."]
521 
(17) In NEC, Section 334.80, the second paragraph is deleted.
522 
(18) In NEC, Section 338.24, the last sentence is deleted and replaced with the following:
523 
"For flat cables, the minor diameter dimension of the cable shall be used to determine
524 
the bending radius when bending on the flat side of the cable. For all other bends, the
525 
major diameter dimension shall be used."
526 
(19) In NEC, Section 406.9(B) number (2),  the following words are deleted:
527 
"be listed weather-resistant type, and installation shall".
528 
(20) NEC, Section 700.3(A) is deleted and replaced with the following:
529 
"700.3(A) Conductor Witness Test.
530 
The authority having jurisdiction shall conduct or witness a test of the complete
531 
system upon installation and periodically afterward."
532 
Section 6.  Section 19-2-107.7 is amended to read:
533 
19-2-107.7 . Water heater regulations.
534 
(1) As used in this section:
535 
(a) "Natural gas-fired water heater" means a device that heats water by the combustion
536 
of natural gas to a thermostatically-controlled temperature not exceeding 210 degrees
537 
Fahrenheit for use external to the vessel at pressures not exceeding 160 pounds per
538 
square inch gauge.
539 
(b) "Ozone nonattainment area" means an area that does not meet the primary or
540 
secondary air quality standards for ozone under the national ambient air quality
541 
standards described in 42 U.S.C. Sec. 7407(d).
542 
(c) "PM2.5 nonattainment area" means an area that does not meet the primary or
543 
secondary air quality standards for fine particulate matter, PM2.5, under the national
544 
ambient air quality standards described in 42 U.S.C. Sec. 7407(d).
545 
[(b)] (d) "Recreational vehicle" means a motor home, travel trailer, truck camper, or
546 
camping trailer, with or without motive power, designed for human habitation for
547 
recreational, emergency, or other occupancy.
548 
(2) A person may not sell or purchase a natural gas-fired water heater that is manufactured
549 
after July 1, 2018 with the intent to install it in Utah if the natural gas-fired water heater
550 
exceeds the applicable nitrogen oxide emission rate limit set in Title 15A, State
551 
Construction and Fire Codes Act.
- 17 - H.B. 313	Enrolled Copy
552 
(3) A manufacturer in Utah shall display the model number and nitrogen oxide emission
553 
rate of a water heater complying with this section on:
554 
(a) the shipping carton for the water heater; and
555 
(b) the permanent rating plate of each water heater unit.
556 
(4) This section does not apply to a water heater unit that:
557 
(a) uses a fuel other than natural gas;
558 
(b) is used in a recreational vehicle; [or]
559 
(c) is manufactured in Utah for shipment and use outside of Utah[.] ; or
560 
(d) is intended to be installed in an area of Utah that is not included in an ozone
561 
nonattainment area or a PM2.5 nonattainment area.
562 
Section 7.  Effective Date.
563 
This bill takes effect on July 1, 2025.
564 
Section 8.  Coordinating H.B. 313 with H.B. 175.
565 
If H.B. 313, State Construction and Electrical Standards Amendments, and H.B. 175,
566 
Housing Construction Amendments, both pass and become law, the Legislature intends that,
567 
on July 1, 2025, the amendments to Section 15A-3-202 in H.B. 313 supersede the amendments
568 
to Section 15A-3-202 in H.B. 175.
- 18 -