Utah 2025 Regular Session

Utah House Bill HB0313 Compare Versions

OldNewDifferences
1-Enrolled Copy H.B. 313
1+03-06 15:55 4th Sub. (Green) H.B. 313
2+Calvin R. Musselman proposes the following substitute bill:
23 1
34 Construction Industry Amendments
45 2025 GENERAL SESSION
56 STATE OF UTAH
67 Chief Sponsor: Thomas W. Peterson
78 Senate Sponsor: Calvin R. Musselman
89 2
910
1011 3
1112 LONG TITLE
1213 4
1314 General Description:
1415 5
1516 This bill modifies the State Construction Code.
1617 6
1718 Highlighted Provisions:
1819 7
1920 This bill:
2021 8
2122 ▸ amends the State Construction Code to:
2223 9
2324 ● align with updated standards in the International Residential Code (IRC); and
2425 10
2526 ● align with the updated standards in the National Electric Code (NEC);
2627 11
2728 ▸ includes a coordination clause to make the amendments to Section 15A-3-202 in this bill
2829 12
2930 supersede the amendments to Section 15A-3-202 in H.B. 175, Housing Construction
3031 13
3132 Amendments;
3233 14
3334 ▸ removes regulations for water heaters in certain areas; and
3435 15
3536 ▸ makes technical changes.
3637 16
3738 Money Appropriated in this Bill:
3839 17
3940 None
4041 18
4142 Other Special Clauses:
4243 19
4344 This bill provides a special effective date.
4445 20
4546 This bill provides a coordination clause.
4647 21
4748 Utah Code Sections Affected:
4849 22
4950 AMENDS:
5051 23
5152 15A-2-103, as last amended by Laws of Utah 2024, Chapter 505
5253 24
5354 15A-3-105, as last amended by Laws of Utah 2024, Chapter 505
5455 25
5556 15A-3-202, as last amended by Laws of Utah 2024, Chapter 505
5657 26
5758 15A-3-206, as last amended by Laws of Utah 2024, Chapter 505
5859 27
59-15A-3-601, as last amended by Laws of Utah 2024, Chapter 15 H.B. 313 Enrolled Copy
60+15A-3-601, as last amended by Laws of Utah 2024, Chapter 15
6061 28
6162 19-2-107.7, as enacted by Laws of Utah 2016, Chapter 247
63+4th Sub. H.B. 313 4th Sub. (Green) H.B. 313 03-06 15:55
6264 29
6365 Utah Code Sections affected by Coordination Clause:
6466 30
6567 15A-3-202, as last amended by Laws of Utah 2024, Chapter 505
6668 31
6769
6870 32
6971 Be it enacted by the Legislature of the state of Utah:
7072 33
7173 Section 1. Section 15A-2-103 is amended to read:
7274 34
7375 15A-2-103 . Specific editions adopted of construction code of a nationally
7476 35
7577 recognized code authority.
7678 36
7779 (1) Subject to the other provisions of this part, the following construction codes are
7880 37
7981 incorporated by reference, and together with the amendments specified in Chapter 3,
8082 38
8183 Statewide Amendments Incorporated as Part of State Construction Code, and Chapter 4,
8284 39
8385 Local Amendments Incorporated as Part of State Construction Code, are the
8486 40
8587 construction standards to be applied to building construction, alteration, remodeling, and
8688 41
8789 repair, and in the regulation of building construction, alteration, remodeling, and repair
8890 42
8991 in the state:
9092 43
9193 (a) the 2021 edition of the International Building Code, including Appendices C and J,
9294 44
9395 issued by the International Code Council;
9496 45
9597 (b) the 2021 edition of the International Residential Code, issued by the International
9698 46
9799 Code Council;
98100 47
99101 (c) Appendix AQ of the 2021 edition of the International Residential Code, issued by the
100102 48
101103 International Code Council;
102104 49
103105 (d) the 2021 edition of the International Plumbing Code, issued by the International
104106 50
105107 Code Council;
106108 51
107109 (e) the 2021 edition of the International Mechanical Code, issued by the International
108110 52
109111 Code Council;
110112 53
111113 (f) the 2021 edition of the International Fuel Gas Code, issued by the International Code
112114 54
113115 Council;
114116 55
115117 (g) the [2020] 2023 edition of the National Electrical Code, issued by the National Fire
116118 56
117119 Protection Association;
118120 57
119121 (h) the 2021 edition of the International Energy Conservation Code, issued by the
120122 58
121123 International Code Council;
122124 59
123125 (i) the 2021 edition of the International Existing Building Code, issued by the
124126 60
125127 International Code Council;
126128 61
127129 (j) subject to Subsection 15A-2-104(2), the HUD Code;
128-- 2 - Enrolled Copy H.B. 313
129130 62
130131 (k) subject to Subsection 15A-2-104(1), Appendix AE of the 2021 edition of the
132+- 2 - 03-06 15:55 4th Sub. (Green) H.B. 313
131133 63
132134 International Residential Code, issued by the International Code Council;
133135 64
134136 (l) subject to Subsection 15A-2-104(1), the 2005 edition of the NFPA 225 Model
135137 65
136138 Manufactured Home Installation Standard, issued by the National Fire Protection
137139 66
138140 Association;
139141 67
140142 (m) subject to Subsection (3), for standards and guidelines pertaining to plaster on a
141143 68
142144 historic property, as defined in Section 9-8a-302, the U.S. Department of the Interior
143145 69
144146 Secretary's Standards for Rehabilitation and Guidelines for Rehabilitating Historic
145147 70
146148 Buildings;[ and]
147149 71
148150 (n) the residential provisions of the 2021 edition of the International Swimming Pool
149151 72
150152 and Spa Code, issued by the International Code Council; and
151153 73
152154 (o) Modular Building Institute Standards 1200 and 1205, issued by the International
153155 74
154156 Code Council, except as modified by provisions of this title governing modular units.
155157 75
156158 (2) Consistent with Title 65A, Chapter 8, Management of Forest Lands and Fire Control,
157159 76
158160 the Legislature adopts the 2006 edition of the Utah Wildland Urban Interface Code,
159161 77
160162 issued by the International Code Council, with the alternatives or amendments approved
161163 78
162164 by the Utah Division of Forestry, Fire, and State Lands, as a construction code that may
163165 79
164166 be adopted by a local compliance agency by local ordinance or other similar action as a
165167 80
166168 local amendment to the codes listed in this section.
167169 81
168170 (3) The standards and guidelines described in Subsection (1)[(n) ] (m) apply only if:
169171 82
170172 (a) the owner of the historic property receives a government tax subsidy based on the
171173 83
172174 property's status as a historic property;
173175 84
174176 (b) the historic property is wholly or partially funded by public money; or
175177 85
176178 (c) the historic property is owned by a government entity.
177179 86
178180 Section 2. Section 15A-3-105 is amended to read:
179181 87
180182 15A-3-105 . Amendments to Chapters 10 through 12 of IBC.
181183 88
182184 (1) In IBC, Section 1010.2.4, number (2), the following is added at the end of the sentence:
183185 89
184186 "Blended assisted living facilities shall comply with Section 1010.2.14.1."
185187 90
186188 (2) A new IBC Section 1010.2.14.1 is added as follows: "1010.2.14.1 Blended assisted
187189 91
188190 living facilities. In occupancy Group I-1, Condition 2 or Group I-2, a Type-II assisted
189191 92
190192 living facility licensed by the Department of Health and Human Services for residents
191193 93
192194 with Alzheimer's or dementia, and having a controlled egress locking system to prevent
193195 94
194196 operation from the egress side shall be permitted to also house residents without a
195197 95
196198 clinical need for their containment where all of the following provisions are met:
197-- 3 - H.B. 313 Enrolled Copy
198199 96
199200 (a) locks in the means of egress comply with all IBC requirements for controlled egress
201+- 3 - 4th Sub. (Green) H.B. 313 03-06 15:55
200202 97
201203 doors;
202204 98
203205 (b) all residents without a clinical need for their containment shall have the keys, codes,
204206 99
205207 or other means necessary to exit the facility, in a manner that is determined by the
206208 100
207209 facility operator and communicated to the resident or their legal representative;
208210 101
209211 (c) residents or their legal representative acknowledge in writing that they understand
210212 102
211213 and agree to living in a facility where egress is controlled; and
212214 103
213215 (d) the number of residents housed in a smoke compartment with controlled egress shall
214216 104
215217 not be greater than 30."
216218 105
217219 (3) In IBC, Section 1011.5.2, exception 3 is deleted and replaced with the following: " 3. In
218220 106
219221 Group R-3 occupancies, within dwelling units in Group R-2 occupancies, and in Group
220222 107
221223 U occupancies that are accessory to a Group R-3 occupancy, or accessory to individual
222224 108
223225 dwelling units in Group R-2 occupancies, the maximum riser height shall be 8 inches
224226 109
225227 (203 mm) and the minimum tread depth shall be 9 inches (229 mm). The minimum
226228 110
227229 winder tread depth at the walk line shall be 10 inches (254 mm), and the minimum
228230 111
229231 winder tread depth shall be 6 inches (152 mm). A nosing not less than 0.75 inch (19.1
230232 112
231233 mm) but not more than 1.25 inches (32 mm) shall be provided on stairways with solid
232234 113
233235 risers where the tread depth is less than 10 inches (254 mm)."
234236 114
235237 (4) In IBC, Section 1011.11, a new exception 6 is added as follows: " 6. In occupancies in
236238 115
237239 Group R-3, as applicable in Section 101.2 and in occupancies in Group U, which are
238240 116
239241 accessory to an occupancy in Group R-3, as applicable in Section 101.2, handrails shall
240242 117
241243 be provided on at least one side of stairways consisting of four or more risers."
242244 118
243245 (5) In IBC, Section 1025, is deleted.
244246 119
245247 (6) In IBC, Section 1104.4, exception 1.5 is deleted.
246248 120
247249 The following section is affected by a coordination clause at the end of this bill.
248250 121
249251 Section 3. Section 15A-3-202 is amended to read:
250252 122
251253 15A-3-202 . Amendments to Chapters 1 through 5 of IRC.
252254 123
253255 (1) In IRC, Section R101.2, Exception, the words "where provided with an automatic
254256 124
255257 sprinkler system complying with Section P2904" are deleted.
256258 125
257259 (2) In IRC, Section R101.2, Exception, the words "6. A triplex or fourplex of no more than
258260 126
259261 two levels with 2-hour fire-resistance-rated vertical shared wall assemblies tested in
260262 127
261263 accordance with ASTM E119 or UL263, 1-hour fire-resistance-rated horizontal floor
262264 128
263265 assemblies tested in accordance with ASTM E119 or UL263, and independent egress for
264266 129
265267 each unit." are added.
266-- 4 - Enrolled Copy H.B. 313
267268 130
268269 [(2)] (3) In IRC, Section R102, a new Section R102.7.2 is added as follows: "R102.7.2
270+- 4 - 03-06 15:55 4th Sub. (Green) H.B. 313
269271 131
270272 Physical change for bedroom window egress. A structure whose egress window in an
271273 132
272274 existing bedroom is smaller than required by this code, and that complied with the
273275 133
274276 construction code in effect at the time that the bedroom was finished, is not required to
275277 134
276278 undergo a physical change to conform to this code if the change would compromise the
277279 135
278280 structural integrity of the structure or could not be completed in accordance with other
279281 136
280282 applicable requirements of this code, including setback and window well requirements."
281283 137
282284 [(3)] (4) In IRC Section R105.2, under Building, the following changes are made:
283285 138
284286 (a) Number 3 is deleted and replaced with the following: "3. Retaining walls retaining
285287 139
286288 less than 4 feet (1219mm) of unbalanced fill, unless supporting a surcharge or
287289 140
288290 requiring design per Section R404.4."
289291 141
290292 (b) Number 10 is deleted and replaced with the following: "10. Decks that are not more
291293 142
292294 than 30 inches (762mm) above grade at any point and not requiring guardrails, that
293295 143
294296 do not serve exit door required by Section R311.4."
295297 144
296298 [(4)] (5) In IRC, Section R105.2, a new exception is added: "11. Grade level, non-connected
297299 145
298300 conex boxes, less than 350 square feet, used for storage only."
299301 146
300302 [(5)] (6) In IRC, Section R108.3, the following sentence is added at the end of the section:
301303 147
302304 "The building official shall not request proprietary information."
303305 148
304306 [(6)] (7) In IRC, Section 109.1.5, is deleted and replaced with the following: "R109.1.5
305307 149
306308 Other inspections. In addition to the inspections listed in R109.1.1 through R109.1.4, the
307309 150
308310 building official shall have the authority to inspect the proper installation of insulation.
309311 151
310312 R109.1.5.1 Weather-resistant exterior wall envelope inspections. An inspection shall be
311313 152
312314 made of the weather-resistant exterior wall envelope as required by Section R703.1 and
313315 153
314316 flashings as required by Section R703.4 to prevent water from entering the
315317 154
316318 weather-resistive barrier.R109.1.5.2 Fire-resistance-rated construction inspection. Where
317319 155
318320 fire-resistance-rated construction is required between dwelling units or due to location
319321 156
320322 on property, the building official shall require an inspection of such construction after
321323 157
322324 lathing or gypsum board or gypsum panel products are in place, but before any plaster is
323325 158
324326 applied, or before board or panel joints and fasteners are taped and finished."
325327 159
326328 [(7)] (8) In IRC, Section R202, the following definition is added: "ACCESSORY
327329 160
328330 DWELLING UNIT: A habitable living unit created within the existing footprint of a
329331 161
330332 primary owner-occupied single-family dwelling."
331333 162
332334 [(8)] (9) In IRC, Section R202, the definition for "Approved" is modified by adding the
333335 163
334336 words "or independent third-party licensed engineer or architect and submitted to the
335-- 5 - H.B. 313 Enrolled Copy
336337 164
337338 building official" after the word "official."
339+- 5 - 4th Sub. (Green) H.B. 313 03-06 15:55
338340 165
339341 [(9)] (10) In IRC, Section R202, the definition for "Approved Agency" is modified by
340342 166
341343 replacing the word "and" with "or."
342344 167
343345 [(10)] (11) In IRC, Section 202, the definition for "Approved Source" is modified by adding
344346 168
345347 the words "or licensed engineer or architect" after the word "official."
346348 169
347349 [(11)] (12) In IRC, Section R202, the following definition is added: "CERTIFIED
348350 170
349351 BACKFLOW PREVENTER ASSEMBLY TESTER: A person who has shown
350352 171
351353 competence to test Backflow prevention assemblies to the satisfaction of the authority
352354 172
353355 having jurisdiction under Utah Code, Subsection 19-4-104(4)."
354356 173
355357 [(12)] (13) In IRC, Section R202, the definition of "Cross Connection" is deleted and
356358 174
357359 replaced with the following: "CROSS CONNECTION. Any physical connection or
358360 175
359361 potential connection or arrangement between two otherwise separate piping systems,
360362 176
361363 one of which contains potable water and the other either water of unknown or
362364 177
363365 questionable safety or steam, gas, or chemical, whereby there exists the possibility for
364366 178
365367 flow from one system to the other, with the direction of flow depending on the pressure
366368 179
367369 differential between the two systems (see "Backflow, Water Distribution")."
368370 180
369371 [(13)] (14) In IRC, Section 202, the following definition is added: "DUAL SOURCE
370372 181
371373 CONNECTION. A pipe that is installed so that either the nonpotable (i.e. secondary)
372374 182
373375 irrigation water or the potable water is connected to a pressurized irrigation system at
374376 183
375377 one time, but not both at the same time; or a pipe that is installed so that either the
376378 184
377379 potable water or private well water is connected to a residence at one time, but not both
378380 185
379381 at the same time. The potable water supply line shall be protected by a reduced pressure
380382 186
381383 backflow preventer."
382384 187
383385 [(14)] (15) In IRC, Section 202, the following definition is added: "ENERGY STORAGE
384386 188
385387 SYSTEM (ESS). One or more devices, assembled together, that are capable of storing
386388 189
387389 energy for supplying electrical energy at a future time."
388390 190
389391 [(15)] (16) In IRC, Section 202, in the definition for gray water a comma is inserted after the
390392 191
391393 word "washers"; the word "and" is deleted; and the following is added to the end: "and
392394 192
393395 clear water wastes which have a pH of 6.0 to 9.0; are non-flammable; non-combustible;
394396 193
395397 without objectionable odors; non-highly pigmented; and will not interfere with the
396398 194
397399 operation of the sewer treatment facility."
398400 195
399401 [(16)] (17) In IRC, Section R202, the definition of "Potable Water" is deleted and replaced
400402 196
401403 with the following: "POTABLE WATER. Water free from impurities present in
402404 197
403405 amounts sufficient to cause disease or harmful physiological effects and conforming to
404-- 6 - Enrolled Copy H.B. 313
405406 198
406407 the Utah Code, Title 19, Chapter 4, Safe Drinking Water Act, and Title 19, Chapter 5,
408+- 6 - 03-06 15:55 4th Sub. (Green) H.B. 313
407409 199
408410 Water Quality Act, and the regulations of the public health authority having jurisdiction."
409411 200
410412 [(17)] (18) In IRC, Figure R301.2 (3), is deleted and replaced with R301.2 (3) as follows:
411413 201 "TABLE R301.2 (3)202
412414 GROUND SNOW LOADS FOR SELECTED LOCATIONS IN UTAH
413415 203
414416 City/Town County Ground Snow Load (lb/ft2)Elevation (ft)
415417 204
416418 Beaver Beaver 35 5886
417419 205
418420 Brigham City Box Elder 42 4423
419421 206
420422 Castle Dale Emery 32 5669
421423 207
422424 Coalville Summit 57 5581
423425 208
424426 Duchesne Duchesne 39 5508
425427 209
426428 Farmington Davis 35 4318
427429 210
428430 Fillmore Millard 30 5138
429431 211
430432 Heber City Wasatch 60 5604
431433 212
432434 Junction Piute 27 6030
433435 213
434436 Kanab Kane 25 4964
435437 214
436438 Loa Wayne 37 7060
437439 215
438440 Logan Cache 43 4531
439441 216
440442 Manila Daggett 26 6368
441443 217
442444 Manti Sanpete 37 5620
443445 218
444446 Moab Grand 21 4029
445447 219
446448 Monticello San Juan 67 7064
447449 220
448450 Morgan Morgan 52 5062
449451 221
450452 Nephi Juab 39 5131
451453 222
452454 Ogden Weber 37 4334
453455 223
454456 Panguitch Garfield 41 6630
455457 224
456458 Parowan Iron 32 6007
457459 225
458460 Price Carbon 31 5558
459-- 7 - H.B. 313 Enrolled Copy
460-226 Provo Utah 31 4541227
461-Randolph Rich 50 6286
462-228
461+226
462+Provo Utah 31 4541
463+- 7 - 4th Sub. (Green) H.B. 313 03-06 15:55
464+227 Randolph Rich 50 6286228
463465 Richfield Sevier 27 5338
464466 229
465467 St. George Washington 21 2585
466468 230
467469 Salt Lake City Salt Lake 28 4239
468470 231
469471 Tooele Tooele 35 5029
470472 232
471473 Vernal Uintah 39 5384
472474 233
473475 Note: To convert lb/ft2 to kN/m2, multiply by 0.0479. To convert feet to meters, multiply by 0.3048.1.
474476 Statutory requirements of the Authority Having Jurisdiction are not included in this state ground snow
475477 load table.
476478 2. For locations where there is substantial change in altitude over the city/town, the load applies at and
477479 below the cited elevation, with a tolerance of 100 ft (30 m).
478480 3. For other locations in Utah, see Bean, B., Maguire, M., Sun, Y. (2018), "The Utah Snow Load
479481 Study," Utah State University Civil and Environmental Engineering Faculty Publications, Paper 3589,
480482 http://utahsnowload.usu.edu/, for ground snow load values."
481483 234
482484 [(18)] (19) In IRC, Section R301.6, is deleted and replaced with the following: "R301.6
483485 235
484486 Utah Snow Loads. The snow loads specified in Table R301.2(5b) shall be used for the
485487 236
486488 jurisdictions identified in that table. Otherwise, for other locations in Utah, see Bean,
487489 237
488490 B., Maguire, M., Sun, Y. (2018), "The Utah Snow Load Study," Utah State University
489491 238
490492 Civil and Environmental Engineering Faculty Publications, Paper 3589,
491493 239
492494 http://utahsnowload.usu.edu/, for ground snow load values."
493495 240
494496 [(19)] (20) In IRC, Section R302.2, the following sentence is added at the end of the
495497 241
496498 paragraph: "When an access/maintenance agreement or easement is in place, plumbing,
497499 242
498500 mechanical ducting, schedule 40 steel gas pipe, and electric service conductors including
499501 243
500502 feeders, are permitted to penetrate the common wall at grade, above grade, or below
501503 244
502504 grade."
503505 245
504506 [(20)] (21) In IRC, Section R302.3, a new exception 3 is added as follows: "3. Accessory
505507 246
506508 dwelling units separated by walls or floor assemblies protected by not less than 1/2-inch
507509 247
508510 (12.7 mm) gypsum board or equivalent on each side of the wall or bottom of the floor
509511 248
510512 assembly are exempt from the requirements of this section."
511513 249
512514 [(21)] (22) In IRC, Section R302.5.1, the last sentence is deleted.
513515 250
514516 [(22)] (23) In IRC, Section R302.13, is deleted.
515-- 8 - Enrolled Copy H.B. 313
516517 251
517518 [(23)] (24) In IRC, Section R303.4, the following exception is added: "Exception: Dwelling
519+- 8 - 03-06 15:55 4th Sub. (Green) H.B. 313
518520 252
519521 units tested in accordance with Section N1102.4.1.2 (R402.4.1.2) which has an air
520522 253
521523 tightness of 3.0 ACH (50) or greater do not require mechanical ventilation."
522524 254
523525 [(24)] (25) In IRC, Section R310.1, all words in the last sentence after "or to a yard or
524526 255
525527 court", are deleted, and Exception 3 of this section is deleted.
526528 256
527529 [(25)] (26) In IRC, Section R310.7, in the exception, the words "or accessory dwelling
528530 257
529531 units" are added after the words "sleeping rooms".
530532 258 [(26)] (27) IRC, Sections R311.7.45 through R311.7.5.3, are deleted and replaced with the
531533 259
532534 following: "R311.7.45.1 Stair treads and risers. R311.7.5.1 Riser height. The maximum riser
533535 260
534536 height shall be 8 inches (203 mm). The riser shall be measured vertically between leading
535537 261
536538 edges of the adjacent treads. The greatest riser height within any flight of stairs shall not
537539 262
538540 exceed the smallest by more than 3/8 inch (9.5 mm).
539541 263
540542 R311.7.5.2 Tread depth. The minimum tread depth shall be 9 inches (228 mm). The
541543 264
542544 tread depth shall be measured horizontally between the vertical planes of the foremost
543545 265
544546 projection of adjacent treads and at a right angle to the tread's leading edge. The greatest tread
545547 266
546548 depth within any flight of stairs shall not exceed the smallest by more than 3/8 inch (9.5 mm).
547549 267
548550 Winder treads shall have a minimum tread depth of 10 inches (254 mm) measured as above at
549551 268
550552 a point 12 inches (305 mm) from the side where the treads are narrower. Winder treads shall
551553 269
552554 have a minimum tread depth of 6 inches (152 mm) at any point. Within any flight of stairs, the
553555 270
554556 greatest winder tread depth at the 12-inch (305 mm) walk line shall not exceed the smallest by
555557 271
556558 more than 3/8 inch (9.5 mm).
557559 272
558560 R311.7.5.3 Nosing. The radius of curvature at the leading edge of the tread shall be no
559561 273
560562 greater than 9/16 inch (14.3 mm). A nosing not less than 3/4 inch (19 mm) but not more than
561563 274
562564 1 1/4 inches (32 mm) shall be provided on stairways with solid risers. The greatest nosing
563565 275
564566 projection shall not exceed the smallest nosing projection by more than 3/8 inch (9.5 mm)
565567 276
566568 between two stories, including the nosing at the level of floors and landings. Beveling of
567569 277
568570 nosing shall not exceed 1/2 inch (12.7 mm). Risers shall be vertical or sloped from the
569571 278
570572 underside of the leading edge of the tread above at an angle not more than 30 degrees (0.51
571573 279
572574 rad) from the vertical. Open risers are permitted, provided that the opening between treads
573575 280
574576 does not permit the passage of a 4-inch diameter (102 mm) sphere.
575577 281
576578 Exceptions.
577579 282
578580 1. A nosing is not required where the tread depth is a minimum of 10 inches (254 mm).
579581 283
580582 2. The opening between adjacent treads is not limited on stairs with a total rise of 30
581583 284
582584 inches (762 mm) or less."
583-- 9 - H.B. 313 Enrolled Copy
584585 285
585586 [(27)] (28) In IRC, Section R312.2, is deleted.
587+- 9 - 4th Sub. (Green) H.B. 313 03-06 15:55
586588 286
587589 [(28)] (29) In IRC, Sections R313.1 through R313.2.1, are deleted and replaced with the
588590 287
589591 following: "R313.1 Design and installation. When installed, automatic residential fire
590592 288
591593 sprinkler systems for townhouses or one- and two-family dwellings shall be designed
592594 289
593595 and installed in accordance with Section P2904 or NFPA 13D."
594596 290
595597 [(29)] (30) In IRC, Section R314.2.2, the words "accessory dwelling units," are added after
596598 291
597599 the words "Where alterations, repairs."
598600 292
599601 [(30)] (31) In IRC, Section R315.2.2, the words "accessory dwelling units," are added after
600602 293
601603 the words "Where alterations, repairs."
602604 294
603605 [(31)] (32) In IRC, Section 315.3, the following words are added to the first sentence after
604606 295
605607 the word "installed": "on each level of the dwelling unit and."
606608 296 [(32)] (33) A new IRC, Section R328.12, is added as follows:
607609 297
608610 "R328.12 Signage. A sign located on the exterior of the dwelling shall be installed at a
609611 298
610612 location approved by the authority having jurisdiction which identifies the battery chemistry
611613 299
612614 included in the ESS. This sign shall be of sufficient durability to withstand the environment
613615 300
614616 involved and shall not be handwritten."
615617 301
616618 [(33)] (34) In IRC, Section 403.1.3.5.3, an exception is added as follows: "Exception:
617619 302
618620 Vertical steel in footings shall be permitted to be located while concrete is still plastic
619621 303
620622 and before it has set. Where vertical steel resists placement or the consolidation of
621623 304
622624 concrete around steel is impeded, the concrete shall be vibrated to ensure full contact
623625 305
624626 between the vertical steel and concrete."
625627 306
626628 [(34)] (35) In IRC, Section R403.1.6, a new Exception 3 is added as follows: "3. When
627629 307
628630 anchor bolt spacing does not exceed 32 inches (813 mm) apart, anchor bolts may be
629631 308
630632 placed with a minimum of two bolts per plate section located not less than 4 inches (102
631633 309
632634 mm) from each end of each plate section at interior bearing walls, interior braced wall
633635 310
634636 lines, and at all exterior walls."
635637 311
636638 [(35)] (36) In IRC, Section R403.1.6.1, a new exception is added at the end of Item 2 and
637639 312
638640 Item 3 as follows: "Exception: When anchor bolt spacing does not exceed 32 inches
639641 313
640642 (816 mm) apart, anchor bolts may be placed with a minimum of two bolts per plate
641643 314
642644 section located not less than 4 inches (102 mm) from each end of each plate section at
643645 315
644646 interior bearing walls, interior braced wall lines, and at all exterior walls."
645647 316
646648 [(36)] (37) In IRC, Section R404.1, a new exception is added as follows: "Exception: As an
647649 317
648650 alternative to complying with Sections R404.1 through R404.1.5.3, concrete and
649651 318
650652 masonry foundation walls may be designed in accordance with IBC Sections 1807.1.5
651-- 10 - Enrolled Copy H.B. 313
652653 319
653654 and 1807.1.6 as amended in Section 1807.1.6.4 and Table 1807.1.6.4 under these rules."
655+- 10 - 03-06 15:55 4th Sub. (Green) H.B. 313
654656 320
655657 [(37)] (38) In IRC, Section R405.1, a second exception is added as follows: "Exception:
656658 321
657659 When a geotechnical report has been provided for the property, a drainage system is not
658660 322
659661 required unless the drainage system is required as a condition of the geotechnical report.
660662 323
661663 The geotechnical report shall make a recommendation regarding a drainage system."
662664 324
663665 [(38)] (39) In IRC, Section R506.2.3, the words "10-mil (0.010 inch; 0.25 mm)" are deleted
664666 325
665667 and replaced with "6-mil (0.006 inch; 0.152 mm)" and the words "conforming to ASTM
666668 326
667669 E1745 Class A requirements" are deleted.
668670 327
669671 (40) In IRC, Section 507.2.1, Wood materials. The following sentence is added after the
670672 328
671673 words, "in accordance with section R317," "field applied weather resistant barrier
672674 329
673675 applied to the top of untreated material,".
674676 330
675677 Section 4. Section 15A-3-206 is amended to read:
676678 331
677679 15A-3-206 . Amendments to Chapters 36, 37, 39, and 44 and Appendix F of IRC.
678680 332
679681 (1) In IRC, Section E3601.6.2, a new exception is added as follows: "Exception: An
680682 333
681683 occupant of an accessory dwelling unit is not required to have access to the disconnect
682684 334
683685 serving the dwelling unit in which they reside."
684686 335
685687 (2) IRC, Section E3606.5, is deleted.
686688 336 (3) IRC, Section E3601.7, is deleted and replaced with the following:
687689 337
688690 "3601.7 Maximum number of disconnects. The service disconnecting means shall consist of
689691 338
690692 not more than six switches or six sets of circuit breakers mounted in a single enclosure or in a
691693 339
692694 group of separate enclosures."
693695 340
694696 (4) In IRC, Section E3705.4.4, the following sentences are deleted:
695697 341
696698 "Where more than two NM cables containing two or more current-carrying
697699 342
698700 conductors are installed, without maintaining space between the cables, through the
699701 343
700702 same opening in wood framing should be sealed with thermal insulation, caulk or
701703 344
702704 sealing foam. The allowable ampacity of each conductor shall be adjusted in accordance
703705 345
704706 with Table E3705.3 and the provisions of Section E3701.3. Exception. may not apply."
705707 346 (5) IRC, Section E3901.4.2, is deleted and replaced with the following:
706708 347
707709 "E3901.4.2 Island and Peninsular Countertops and Work Spaces. Receptacle outlets, if
708710 348
709711 installed to serve an island or peninsular countertop or work surface, shall be installed in
710712 349
711713 accordance with E3901.4.3. If a receptacle outlet is not provided to serve an island or
712714 350
713715 peninsular countertop or work surface, provisions shall be provided at the island or peninsula
714716 351
715717 for future addition of a receptacle outlet to serve the island or peninsular countertop or work
716718 352
717719 surface."
718-- 11 - H.B. 313 Enrolled Copy
719-353
720-[(5)] (6) IRC, Section E3901.4.3, is deleted and replaced with the following:
720+353 [(5)] (6) IRC, Section E3901.4.3, is deleted and replaced with the following:
721+- 11 - 4th Sub. (Green) H.B. 313 03-06 15:55
721722 354
722723 "E3901.4.3 Receptacle Outlet Location. [Receptacle] When installed, receptacle outlets
723724 355
724725 shall be located in one or more of the following:
725726 356
726727 1. On or above, but not more than 20 inches (508 mm) above a countertop or work
727728 357
728729 surface.
729730 358
730731 2. In a countertop using receptacle outlet assemblies listed for use in countertops.
731732 359
732733 3. In a work surface using receptacle outlet assemblies listed for use in work surface or
733734 360
734735 listed for use in countertops.
735736 361
736737 Receptacle outlets rendered not readily accessible by appliances fastened in place,
737738 362
738739 appliance garages, sinks, or range tops as covered in the exception to Section E3901.4.1 or
739740 363
740741 appliances occupying assigned spaces shall not be considered as these required outlets.
741742 364
742743 4. Under the countertop not more than 14 inches from the bottom leading edge of the
743744 365
744745 countertop."
745746 366
746747 [(6)] (7) In IRC, Section 3902.1, after the word "125-volt" add "single phase 15 and 20
747748 367
748749 ampere" and strike the words "through 250 volt."
749750 368
750751 [(7)] (8) In IRC, Section 3902.2, after the word "125-volt" add "single phase 15 and 20
751752 369
752753 ampere" and strike the words "through 250 volt."
753754 370
754755 [(8)] (9) In IRC, Section 3902.3, after the word "125-volt" add "single phase 15 and 20
755756 371
756757 ampere" and strike the words "through 250 volt."
757758 372
758759 [(9)] (10) In IRC, Section 3902.4, after the word "125-volt" add "single phase 15 and 20
759760 373
760761 ampere" and strike the words "through 250 volt."
761762 374
762763 [(10)] (11) In IRC, Section 3902.5, after the word "125-volt" add the words "single phase 15
763764 375
764765 and 20 ampere in unfinished portions of the basement shall have ground-fault
765766 376
766767 circuit-interrupter protection for personnel" and delete the rest of the section.
767768 377
768769 [(11)] (12) In IRC, Section 3902.6, after the word "125-volt" add "single phase 15 and 20
769770 378
770771 ampere" and strike the words "through 250 volt."
771772 379
772773 [(12)] (13) In IRC, Section 3902.7, after the word "125-volt" add "single phase 15 and 20
773774 380
774775 ampere" and strike the words "through 250 volt."
775776 381
776777 [(13)] (14) In IRC, Section 3902.8, after the word "125-volt" add "single phase 15 and 20
777778 382
778779 ampere" and strike the words "through 250 volt."
779780 383
780781 [(14)] (15) In IRC, Section 3902.9, after the word "125-volt" add "single phase 15 and 20
781782 384
782783 ampere" and strike the words "through 250 volt."
783784 385
784785 [(15)] (16) IRC, Section 3902.10, is deleted.
785786 386
786787 [(16)] (17) In IRC, Section 3902.12, after the word "125-volt" add "single phase 15 and 20
787-- 12 - Enrolled Copy H.B. 313
788788 387
789789 ampere" and strike the words "through 250 volt."
790+- 12 - 03-06 15:55 4th Sub. (Green) H.B. 313
790791 388
791792 [(17)] (18) In IRC, Section 3902.13, after the word "125-volt" add "single phase 15 and 20
792793 389
793794 ampere" and strike the words "through 250 volt."
794795 390
795796 [(18)] (19) IRC, Section 3902.15, Crawl space lighting outlets, is deleted.
796797 391
797798 [(19)] (20) IRC, Section 3902.16, Equipment requiring servicing, is deleted.
798799 392
799800 [(20)] (21) IRC Section 3902.17, Outdoor outlets, is deleted.
800801 393
801802 [(21)] (22) IRC, Section 3902.19, Location of arc-fault circuit interrupters, is deleted.
802803 394
803804 [(22)] (23) IRC, Section E3902.20, Arc-fault circuit interrupter protection, is deleted.
804805 395
805806 [(23)] (24) IRC, Section E3902.21, Arc-fault circuit interrupter protection for branch circuit
806807 396
807808 extensions or modification, is deleted.
808809 397
809810 [(24)] (25) IRC, Section 4002.11, is deleted and replaced with the following: "4002.11
810811 398
811812 Bathtub and Shower Space. Receptacles shall not be installed within or directly over a
812813 399
813814 bathtub or shower stall."
814815 400
815816 [(25)] (26) IRC, Chapter 44, is amended by deleting the standard for "ANCE."
816817 401
817818 [(26)] (27) In IRC, Chapter 44, the standard for ASHRAE is amended by changing
818819 402
819820 "34-2013" to "34-2019."
820821 403
821822 [(27)] (28) In IRC, Chapter 44, the standard for CSA, is amended by changing the:
822823 404
823824 (a) standard reference number "UL/CSA/ANCE 60335-2-40-2012" to "UL/CSA
824825 405
825826 60335-2-40-2019"; and
826827 406
827828 (b) title "Standard for Household and Similar Electrical Appliances, Part 2: Particular
828829 407
829830 Requirements for Motor-Compressors" to "Standard for Household and Similar
830831 408
831832 Electrical Appliances, Part 2-40, Requirements for Electric Heat Pumps, Air
832833 409
833834 Conditioners and Dehumidifiers-3rd Edition."
834835 410
835836 [(28)] (29) In IRC, Chapter 44, the standard for UL, is amended by changing the:
836837 411
837838 (a) standard reference number "1995-2011" to "1995-2015";
838839 412
839840 (b) standard reference number "UL/CSA/ANCE 60335-2-40-2012" to "UL/CSA
840841 413
841842 60335-2-40-2019"; and
842843 414
843844 (c) title "Standard for Household and Similar Electrical Appliances, Part 2: Particular
844845 415
845846 Requirements for Motor-Compressors" to "Standard for Household and Similar
846847 416
847848 Electrical Appliances, Part 2-40, Requirements for Electric Heat Pumps, Air
848849 417
849850 Conditioners and Dehumidifiers-3rd Edition."
850851 418 [(29)] (30) In IRC, Chapter 44, the standard for ANSI/RESNET/ICC 201-2019 Section 4.4.4 is
851852 419
852853 added as follows: "4.4.4. Air Source Heat Pumps and Air Conditioners. For Heat Pumps and
853854 420
854855 Air Conditioners with the more recent Manufacturers Equipment Performance Ratings (HSPF2
855-- 13 - H.B. 313 Enrolled Copy
856856 421
857857 or SEER2) available, and HSPF and SEER are not available, these ratings shall be converted
858+- 13 - 4th Sub. (Green) H.B. 313 03-06 15:55
858859 422
859860 to HSPF and SEER values by dividing HSPF2 or SEER2 by the conversion factors in Table
860861 423
861862 4.4.4.1(1). If the type of equipment is not determined, the conversion shall default to the
862863 424
863864 Ducted Split System factors. All calculations, including Equation 4.1-1a shall use HSPF or
864865 425
865866 SEER values as made available by the Manufacturer or converted as specified in this section.
866867 426
867868 Table 4.4.4.1(1) SEER2 and HSPF2 Conversion Factors3.
868869 427 Equipment Type SEER2/SEEREER/EER4 HSPF/HSPF428
869870 Ductless Systems 1.00 1.00 0.90
870871 429
871872 Ducted Split System 0.95 0.95 0.85
872873 430
873874 Ducted Package System 0.95 0.95 0.84
874875 431
875876 Small Duct High Velocity System 1.00 not applicable0.85
876877 432
877878 Ducted Space-Constrained Air Conditioner 0.97 not applicablenot applicable
878879 433
879880 Ducted Space-Constrained Heat Pump not applicable0.85"
880881 434 [(30)] (31) IRC, Chapter 44, is amended by adding the following reference standard:
881882 435
882883 436 "Standard reference numberTitle Referenced in code
883884 section number
884885 437
885886 USC-FCCCHR 10th
886887 Edition Manual of Cross
887888 Connection Control
888889 Foundation for Cross-Connection Control and
889890 Hydraulic Research University of Southern
890891 California Kaprielian Hall 300 Los Angeles
891892 CA 90089-2531
892893 Table P2902.3"
893894 438
894895 [(31)] (32) IRC, Chapter 44, is amended by adding the following reference standard: "UL
895896 439
896897 9540-20: Energy Storage Systems and Equipment; R328.1, R328.2, and R328.6."
897898 440
898899 [(32)] (33)(a) When passive radon controls or portions thereof are voluntarily installed,
899900 441
900901 the voluntary installation shall comply with Appendix F of the IRC.
901902 442
902903 (b) An additional inspection of a voluntary installation described in Subsection [(27)(a) ]
903904 443
904905 (28)(a) is not required.
905906 444
906907 Section 5. Section 15A-3-601 is amended to read:
907908 445
908909 15A-3-601 . General provisions.
909910 446
910911 The following are adopted as amendments to the NEC to be applicable statewide:
911912 447
912913 (1) The IRC provisions are adopted as the residential electrical standards applicable to
913914 448
914915 residential installations under the IRC. All other installations shall comply with the
915916 449
916917 adopted NEC.
917-- 14 - Enrolled Copy H.B. 313
918918 450
919919 (2) In NEC, Section 210.8(A), the words "through 250-volt" are deleted.
920+- 14 - 03-06 15:55 4th Sub. (Green) H.B. 313
920921 451
921922 (3) In NEC, Section 210.8(A) number (5), the word "Basements" is deleted and replaced
922923 452
923924 with the following:
924925 453
925926 "Unfinished portions or areas of the basement not intended as habitable rooms."
926927 454
927928 (4) In NEC, Section 210.8(A), number (6), the following is added after the word "Kitchens":
928929 455
929930 "where the receptacles are installed to serve the countertop surfaces."
930931 456
931932 (5) In NEC, Section 210.8(A), number (7) is deleted.
932933 457
933934 (6) In NEC, Section 210.8(D), numbers (8) through (12) are deleted.
934935 458
935936 (7) NEC, Section 210.8(F), is deleted.
936937 459 [(5)] (8) NEC, Sections 210.52(C) number (2) and number (3) are deleted and replaced with the
937938 460
938939 following:
939940 461
940941 "210.52(C)(2) Island and peninsular countertops and Work Surfaces. Receptacle outlets,
941942 462
942943 if installed to serve an island or peninsular countertop or work surface, shall be installed in
943944 463
944945 accordance with 210.52(C)(3). If a receptacle outlet is not provided to serve an island or
945946 464
946947 peninsular countertop or work surface, provisions shall be provided at the island or peninsula
947948 465
948949 for future addition of a receptacle outlet to serve the island or peninsular countertop or work
949950 466
950951 surface.
951952 467
952953 210.2(C)(3) Receptacle outlet location. Receptacle outlets shall be located in one or
953954 468
954955 more of the following:
955956 469
956957 (a) On or above, but not more than 500 mm (20 inches) above a countertop or work
957958 470
958959 surface.
959960 471
960961 (b) In a countertop using receptacle assemblies listed for use in countertops.
961962 472 (c) In a work surface using receptacle outlet assemblies listed for use in work surfaces or listed
962963 473
963964 for use in countertops.
964965 474
965966 Receptacle outlets rendered not readily accessible by appliances fastened in place,
966967 475
967968 appliance garages, sinks, or range tops as covered in the exception to 210.52(C)(1), occupying
968969 476
969970 assigned spaces shall not be considered as these required outlets.
970971 477
971972 Exception: In dwelling units designed to be accessible to persons with disabilities,
972973 478
973974 receptacles shall be permitted to be installed not more than 300 mm (12 inches) below the
974975 479
975976 countertop or work surface. Receptacles installed below a countertop or work surface shall not
976977 480
977978 be located where the countertop or work surface extends more than 150 mm (6 inches) beyond
978979 481
979980 its support or base."
980981 482
981982 [(6)] (9) NEC, Section 210.12, is deleted.
982983 483
983984 [(7)] (10) NEC, Section 210.65, is deleted.
984-- 15 - H.B. 313 Enrolled Copy
985985 484
986986 (11) NEC, Section 215.18, is deleted.
987+- 15 - 4th Sub. (Green) H.B. 313 03-06 15:55
987988 485
988989 (12) NEC, Section 225.42 is deleted.
989990 486
990991 [(8)] (13) NEC, Section 230.67, is deleted.
991992 487 [(9)] (14) NEC, Section 230.71, is deleted and replaced with the following:
992993 488
993994 "230.71 Maximum Number of Disconnects.
994995 489
995996 (A) General. The service disconnecting means for each service permitted by 230.2, or for
996997 490
997998 each set of service-entrance conductors permitted by 230.40, Exception No. 1, 3, 4, or 5 shall
998999 491
9991000 consist of not more than six switches or sets of circuit breakers, or a combination of not more
10001001 492
10011002 than six switches and sets of circuit breakers, mounted in a single enclosure, in a group of
10021003 493
10031004 separate enclosures, or in or on a switchboard or in switchgear. There shall be not more than
10041005 494
10051006 six sets of disconnects per service grouped in any one location. For the purpose of this section,
10061007 495
10071008 disconnecting means installed as part of listed equipment and used solely for the following
10081009 496
10091010 shall not be considered a service disconnecting means:
10101011 497
10111012 (1) Power monitoring equipment;
10121013 498
10131014 (2) Surge-protective device(s);
10141015 499
10151016 (3) Control circuit of the ground-fault protection system; or
10161017 500
10171018 (4) Power-operable service disconnecting.
10181019 501
10191020 (B) Single-Pole Units. Two or three single-pole switches or breakers, capable of individual
10201021 502
10211022 operation, shall be permitted on multiwire circuits, one pole for each ungrounded conductor, as
10221023 503
10231024 one multipole disconnect, provided they are equipped with identified handle ties or a master
10241025 504
10251026 handle to disconnect all conductors of the service with no more than six operations of the hand.
10261027 505
10271028 (C) Beginning on July 1, 2027, Section 230.71(B) is no longer in effect."
10281029 506
10291030 [(10)] (15) NEC, Section 314.27(C), is deleted and replaced with the following: "314.27(C)
10301031 507
10311032 Boxes at Ceiling-Suspended (Paddle) Fan Outlets. Outlet boxes or outlet box systems
10321033 508
10331034 used as the sole support of a ceiling-suspended (paddle) fan shall be listed, shall be
10341035 509
10351036 marked by their manufacturer as suitable for this purpose, and shall not support
10361037 510
10371038 ceiling-suspended (paddle) fans that weigh more than 32 kg (70 lb). For outlet boxes or
10381039 511
10391040 outlet box systems designed to support ceiling-suspended (paddle) fans that weigh more
10401041 512
10411042 than 16 kg (35 lb), the required marking shall include the maximum weight to be
10421043 513
10431044 supported."
10441045 514
10451046 (16) In NEC, Section 334.24, the last sentence is deleted and replaced with the following:
10461047 515
10471048 "For flat cables, the minor diameter dimension of the cable shall be used to determine
10481049 516
10491050 the bending radius when bending on the flat side of the cable. For all other bends, the
10501051 517
10511052 major diameter dimension shall be used."
1052-- 16 - Enrolled Copy H.B. 313
10531053 518
10541054 [(11) NEC, Section 406.9(C), is deleted and replaced with the following: "406.9(C) Bathtub
1055+- 16 - 03-06 15:55 4th Sub. (Green) H.B. 313
10551056 519
10561057 and Shower Space. Receptacles shall not be installed within or directly over a bathtub or
10571058 520
10581059 shower stall."]
10591060 521
10601061 (17) In NEC, Section 334.80, the second paragraph is deleted.
10611062 522
10621063 (18) In NEC, Section 338.24, the last sentence is deleted and replaced with the following:
10631064 523
10641065 "For flat cables, the minor diameter dimension of the cable shall be used to determine
10651066 524
10661067 the bending radius when bending on the flat side of the cable. For all other bends, the
10671068 525
10681069 major diameter dimension shall be used."
10691070 526
10701071 (19) In NEC, Section 406.9(B) number (2), the following words are deleted:
10711072 527
10721073 "be listed weather-resistant type, and installation shall".
10731074 528
10741075 (20) NEC, Section 700.3(A) is deleted and replaced with the following:
10751076 529
10761077 "700.3(A) Conductor Witness Test.
10771078 530
10781079 The authority having jurisdiction shall conduct or witness a test of the complete
10791080 531
10801081 system upon installation and periodically afterward."
10811082 532
10821083 Section 6. Section 19-2-107.7 is amended to read:
1083-533
1084+101
10841085 19-2-107.7 . Water heater regulations.
1085-534
1086+533a
10861087 (1) As used in this section:
1087-535
1088+533b
10881089 (a) "Natural gas-fired water heater" means a device that heats water by the combustion
1089-536
1090+533c
10901091 of natural gas to a thermostatically-controlled temperature not exceeding 210 degrees
1091-537
1092+533d
10921093 Fahrenheit for use external to the vessel at pressures not exceeding 160 pounds per
1093-538
1094+533e
10941095 square inch gauge.
1095-539
1096+533f
10961097 (b) "Ozone nonattainment area" means an area that does not meet the primary or
1097-540
1098+533g
10981099 secondary air quality standards for ozone under the national ambient air quality
1099-541
1100+533h
11001101 standards described in 42 U.S.C. Sec. 7407(d).
1101-542
1102+533i
11021103 (c) "PM2.5 nonattainment area" means an area that does not meet the primary or
1103-543
1104+533j
11041105 secondary air quality standards for fine particulate matter, PM2.5, under the national
1105-544
1106+533k
11061107 ambient air quality standards described in 42 U.S.C. Sec. 7407(d).
1107-545
1108+533l
11081109 [(b)] (d) "Recreational vehicle" means a motor home, travel trailer, truck camper, or
1109-546
1110+533m
11101111 camping trailer, with or without motive power, designed for human habitation for
1111-547
1112+533n
11121113 recreational, emergency, or other occupancy.
1113-548
1114+533o
11141115 (2) A person may not sell or purchase a natural gas-fired water heater that is manufactured
1115-549
1116+533p
11161117 after July 1, 2018 with the intent to install it in Utah if the natural gas-fired water heater
1117-550
1118+533q
11181119 exceeds the applicable nitrogen oxide emission rate limit set in Title 15A, State
1119-551
1120+533r
11201121 Construction and Fire Codes Act.
1121-- 17 - H.B. 313 Enrolled Copy
1122-552
1122+533s
11231123 (3) A manufacturer in Utah shall display the model number and nitrogen oxide emission
1124-553
1124+- 17 - 4th Sub. (Green) H.B. 313 03-06 15:55
1125+533t
11251126 rate of a water heater complying with this section on:
1126-554
1127+533u
11271128 (a) the shipping carton for the water heater; and
1128-555
1129+533v
11291130 (b) the permanent rating plate of each water heater unit.
1130-556
1131+533w
11311132 (4) This section does not apply to a water heater unit that:
1132-557
1133+533x
11331134 (a) uses a fuel other than natural gas;
1134-558
1135+533y
11351136 (b) is used in a recreational vehicle; [or]
1136-559
1137+533z
11371138 (c) is manufactured in Utah for shipment and use outside of Utah[.] ; or
1138-560
1139+533aa
11391140 (d) is intended to be installed in an area of Utah that is not included in an ozone
1140-561
1141+533bb
11411142 nonattainment area or a PM2.5 nonattainment area.
1142-562
1143+533cc
11431144 Section 7. Effective Date.
1144-563
1145+533dd
11451146 This bill takes effect on July 1, 2025.
1146-564
1147+533ee
11471148 Section 8. Coordinating H.B. 313 with H.B. 175.
1148-565
1149+533ff
11491150 If H.B. 313, State Construction and Electrical Standards Amendments, and H.B. 175,
1150-566
1151+533gg
11511152 Housing Construction Amendments, both pass and become law, the Legislature intends that,
1152-567
1153+533hh
11531154 on July 1, 2025, the amendments to Section 15A-3-202 in H.B. 313 supersede the amendments
1154-568
1155+533ii
11551156 to Section 15A-3-202 in H.B. 175.
11561157 - 18 -